WA-CP3A-1E1 - Welch Allyn CP 300™ Electrocardiograph with Optional Stress
High-resolution 15" TFT color display for easy patient data entry and waveform monitoring
See all 12 leads at once as non-interpretive 12-lead resting ECGs come standard with measurements
Optional ECG Interpretation software for both adult and pediatric patients
Lead Quality Detection—with checkpoints/aid on electrode placement lead quality
40GB Storage—plenty of room to store large volumes of test records
Flexible report formats—Full size reports (8.5x11) generated from a high resolution thermal printer enable you to choose from up to 6 different styles
System Specifications:
Dimensions: 100 x 285 x 350 mm (l x w x h)
Weight: 6,8 kg / 15 lbs
Monitor: 15” TFT display, high resolution 1024 x 768 pixels
Interfaces: RS-232 interfaces, 1 LPT bi-directional Centronic interface, Ethernet LAN RJ45
Operator Interface:
- Alphanumeric PC keyboard with glide point
- Direct function keys
- PC mouse and external PC keyboard (optional)
Battery:
- 24 V Lithium-ion rechargeable (built in charger); giving bridging power for at least 60 min
Power consumption: 75 VA
Power supply requirements: 100 – 240 V, 50/60 Hz
Processor:
- Industrial single board computer
- Memory media: Integrated hard disk
- Network card: Integrated
Printing process:
- Integrated high-resolution thermal print head, 8 dots/mm (amplitude axis), 40 dots/mm (time axis),@ 25 mm/s
- Paper speeds: 10 / 25 / 50 mm/sec (manual)
- Chart paper: Thermo reactive, Z-folded, letter size, ready-to-file
- Frequency response of digital recorder: 0 to 150 Hz (IEC/AHA)
- Recording tracks: 6 channels, positioned at optimal width on 200 mm, automatc baseline adjustment
- Sensitivities: 5 / 10 / 20 mm/mV
External printer (optional): Windows™ standard
ECG Measuring Data:
ECG amplifier:
- Simultaneous, synchronous recording of all active electrode signals
- Dynamic range ± 10 mV AC
- Frequency response: 0.05 to 150 Hz (– 3dB)
- Digital resolution: 5 µV
- Maximum electrode potential: ± 300 mV DC
- Time constant: 3.2 sec
- Common mode rejection: > 100 dB / 50 or 60 Hz
- Input Impedance: > 100 M Ohm
Filters:
Powerline Frequency Filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by adaptive digital filtering
Smoothing Filter/Myogram Filter (muscle tremor filter): Adaptive low pass smoothing filter to suppress muscle tremor and high-frequency noise, without affecting the QRS complex
Baseline Stabilizer: Filter to suppress or greatly reduce base line fluctuations without changing the measurement values (for Resting and Exercise ECGs); safety standard: IEC/EN 60601-2-51 (protection against hazardous output)
Safety Standards:
Patient input: Fully floating and isolated, defibrillation protected (only with original SCHILLER patient cable)
IEC/EN 60601-1; UL 60601-1; C22.2 No. 601.1-M90; IEC/EN 60601-2-25; IEC/EN 60601-1-2 (EMC)
Protection Class: I according to IEC/EN 60601-1 (with internal power supply)
Applied Part: CF according IEC/EN 60601-1
Conformity: CE according Directive 93/42/EEC (Medical Devices)
Classification: IIa according Directive 93/92/EEC
Environmental conditions:
Temperature, operating: 10° to 40° C
Temperature, storage: –10° to 50° C
Relative humidity: 25 to 95% (no condensation)
Pressure: 700 to 1060 hPa
Technical data are subject to change without notice.
Welch Allyn CP 300™ Electrocardiograph with Optional Stress: Accessories
Part Number: 45008-0000
Resting Tab Electrodes (box of 1,000) 100 ECGs
Part Number: 58581-0000
Resting Tab Electrode Adapters (10 clips)
Part Number: 102786
Paper--CP 300 (150 sheets/pack)
Part Number: 102787
10-lead patient cable, AHA, CP300, banana plugs, 2m
Part Number: 08265-0000
ECG Utiliy Cart, CP100/CP200/CP300, CP10/20
Part Number: 401393
Office Cart
Part Number: 401394
Hospital Cart
Part Number: 102789
CP300 cart, with shelf & basket
Part Number: 102800
CP300 Shelf
Part Number: 102801
Cable arm for CP300 cart
Part Number: 102802
CP300 Monitor holder including shelf for CP300 cart
Part Number: 58581-0000
Alligator Clips (set of 10)
Part Number: 714250
CP 300 Directions for Use Manual (Printed)
Part Number: 71300-0000
ECG Hookup Wall Chart, English
Part Number: 714250
CP300 Directions for Use Manual
Part Number: 714251
CP300 Interpretation & Meas. Guide
Part Number: 714250
CP300 Service Manual
Part Number: 102891
Interpretation Upgrade (must provide system serial number)
Part Number: 714059
ECG Replacement Battery for CP300
CARRIES FULL MANUFACTURER'S WARRANTY - FREE SHIPPING!!!
|
|